{"id":1035,"date":"2026-05-13T02:59:43","date_gmt":"2026-05-13T02:59:43","guid":{"rendered":"https:\/\/chemomentmaterials.com\/?p=1035"},"modified":"2026-10-11T06:33:32","modified_gmt":"2026-10-11T06:33:32","slug":"can-you-reline-a-crown-impression-with-light-body-vps","status":"publish","type":"post","link":"https:\/\/chemomentmaterials.com\/fr\/can-you-reline-a-crown-impression-with-light-body-vps\/","title":{"rendered":"Peut-on rebaser une empreinte de couronne avec du VPS Light Body ?"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Un petit manque dans une empreinte de couronne pose souvent une question au fauteuil : ajouter du VPS Light Body frais et r\u00e9ins\u00e9rer, ou reprendre l\u2019empreinte ? La r\u00e9ponse d\u00e9pend moins de la taille du d\u00e9faut que de son emplacement, de la r\u00e9insertion exacte et de la lisibilit\u00e9 univoque de la limite au laboratoire.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour les couronnes et bridges, le rebasage doit rester exceptionnel. Le VPS Light Body enregistre des d\u00e9tails fins, mais ne corrige pas une empreinte d\u00e9j\u00e0 d\u00e9form\u00e9e, contamin\u00e9e, insuffisamment ins\u00e9r\u00e9e ou soutenue. Une r\u00e9paration peut sembler acceptable et n\u00e9anmoins produire une couronne n\u00e9cessitant ajustage ou r\u00e9fection.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/chemomentmaterials.com\/wp-content\/uploads\/2026\/05\/Dental-impression-tray-inspection-process-1024x576.jpg\" alt=\"Contr\u00f4le d\u2019une empreinte dentaire dans son porte-empreinte\" class=\"wp-image-1038\" style=\"width:635px;height:auto\" srcset=\"https:\/\/chemomentmaterials.com\/wp-content\/uploads\/2026\/05\/Dental-impression-tray-inspection-process-1024x576.jpg 1024w, https:\/\/chemomentmaterials.com\/wp-content\/uploads\/2026\/05\/Dental-impression-tray-inspection-process-300x169.jpg 300w, https:\/\/chemomentmaterials.com\/wp-content\/uploads\/2026\/05\/Dental-impression-tray-inspection-process-768x432.jpg 768w, https:\/\/chemomentmaterials.com\/wp-content\/uploads\/2026\/05\/Dental-impression-tray-inspection-process-1536x864.jpg 1536w, https:\/\/chemomentmaterials.com\/wp-content\/uploads\/2026\/05\/Dental-impression-tray-inspection-process.jpg 1672w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Que signifie rebaser une empreinte de couronne ?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Il s\u2019agit d\u2019ajouter du VPS Light Body \u00e0 une empreinte d\u00e9j\u00e0 prise et de la r\u00e9ins\u00e9rer pour enregistrer les d\u00e9tails manquants. Cette solution est envisag\u00e9e apr\u00e8s d\u00e9couverte d\u2019une bulle, d\u2019un \u00e9tirement, d\u2019un manque ou d\u2019une zone sous-remplie.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019empreinte initiale a d\u00e9j\u00e0 enregistr\u00e9 une position d\u2019insertion. Apr\u00e8s ajout du mat\u00e9riau fluide, le porte-empreinte doit suivre le m\u00eame trajet sans s\u2019arr\u00eater trop t\u00f4t, basculer ni cr\u00e9er de pression localis\u00e9e. Sinon, le rebasage peut former une surface incompatible avec l\u2019enregistrement initial.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour une couronne, cet \u00e9cart compte. Le laboratoire lit aussi la limite, les tissus mous, les contacts adjacents, l\u2019espace occlusal et les rapports entre pr\u00e9paration et mat\u00e9riau du porte-empreinte.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Peut-on rebaser une empreinte de couronne avec du VPS Light Body ?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Oui, mais dans des cas limit\u00e9s. Un petit d\u00e9faut loin de la limite peut parfois \u00eatre r\u00e9par\u00e9 si l\u2019empreinte est stable, compl\u00e8tement ins\u00e9r\u00e9e et sans d\u00e9chirure. Une petite bulle sur une surface non pr\u00e9par\u00e9e et non critique diff\u00e8re fortement d\u2019un manque sous-gingival.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Si le d\u00e9faut concerne limite, cong\u00e9 profond, \u00e9paulement, zone interproximale, pilier de bridge ou autre zone d\u00e9finissant la restauration, une reprise compl\u00e8te est g\u00e9n\u00e9ralement pr\u00e9f\u00e9rable. Le laboratoire ne doit pas deviner quelle ligne est la vraie limite.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Rebaser ou reprendre : tableau de d\u00e9cision<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Situation clinique<\/th><th>Rebasage au VPS Light Body ?<\/th><th>D\u00e9cision recommand\u00e9e<\/th><\/tr><\/thead><tbody><tr><td>Petite bulle loin de la limite<\/td><td>Parfois<\/td><td>V\u00e9rifier r\u00e9insertion et lisibilit\u00e9 au laboratoire<\/td><\/tr><tr><td>Manque directement sur la limite<\/td><td>Non<\/td><td>Reprendre l\u2019empreinte<\/td><\/tr><tr><td>Couche fluide d\u00e9chir\u00e9e pr\u00e8s d\u2019une limite sous-gingivale<\/td><td>Non<\/td><td>Am\u00e9liorer la ma\u00eetrise du champ et reprendre<\/td><\/tr><tr><td>Porte-empreinte initialement mal ins\u00e9r\u00e9<\/td><td>Non<\/td><td>Reprendre apr\u00e8s correction du chargement et de l\u2019axe d\u2019insertion<\/td><\/tr><tr><td>Limite affect\u00e9e par le sang ou la salive<\/td><td>Non<\/td><td>Ma\u00eetriser l\u2019humidit\u00e9 et reprendre<\/td><\/tr><tr><td>Contact adjacent ou d\u00e9tail proximal flou<\/td><td>G\u00e9n\u00e9ralement non<\/td><td>Reprendre, surtout pour les couronnes et bridges<\/td><\/tr><tr><td>Petit manque non critique sur une surface non pr\u00e9par\u00e9e<\/td><td>\u00c9ventuellement<\/td><td>R\u00e9parer uniquement si la r\u00e9insertion est pr\u00e9visible<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Pourquoi le rebasage peut aggraver l\u2019empreinte<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">R\u00e9insertion incompl\u00e8te<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le VPS Light Body frais ajoute de la mati\u00e8re dans un espace d\u00e9j\u00e0 enregistr\u00e9. Sans voie d\u2019\u00e9vacuation, le porte-empreinte peut s\u2019arr\u00eater trop t\u00f4t. Ce faible \u00e9cart peut affecter l\u2019insertion de la couronne, les contacts et l\u2019occlusion.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Pression hydraulique<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le mat\u00e9riau frais peut cr\u00e9er une pression \u00e0 la r\u00e9insertion, surtout pr\u00e8s des limites profondes, secondes molaires, bo\u00eetes proximales et sulcus \u00e9troits. Cette pression peut d\u00e9former les tissus ou emp\u00eacher une insertion compl\u00e8te plut\u00f4t qu\u2019am\u00e9liorer le relev\u00e9.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Doubles limites<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Si limite initiale et zone rebas\u00e9e ne co\u00efncident pas parfaitement, le proth\u00e9siste peut voir deux limites possibles. Une r\u00e9paration avec des lignes concurrentes est souvent moins utile qu\u2019une reprise nette.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Surface contamin\u00e9e<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le VPS pris peut \u00eatre expos\u00e9 \u00e0 la salive, au sang, \u00e0 la poudre des gants, aux r\u00e9sidus d\u2019adh\u00e9sif ou aux manipulations. La couche neuve peut prendre sans garantir une interface fiable. Les zones fines rebas\u00e9es peuvent aussi se d\u00e9chirer au retrait.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Le manque visible peut masquer le vrai probl\u00e8me<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Une bulle peut r\u00e9v\u00e9ler s\u00e9chage insuffisant, tissus affaiss\u00e9s, insertion tardive, volume fluide insuffisant, viscosit\u00e9s inadapt\u00e9es ou mouvement. Le rebasage remplit le manque sans corriger sa cause.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Pourquoi utiliser le VPS Light Body autour des limites de couronne ?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le VPS Light Body est choisi pour les d\u00e9tails fins. Il circule autour de la pr\u00e9paration, p\u00e9n\u00e8tre les sulcus \u00e9troits et aide \u00e0 enregistrer la limite lorsqu\u2019elle est visible et le champ ma\u00eetris\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La fluidit\u00e9 a ses limites. Sang, salive ou gencive affaiss\u00e9e sur la limite emp\u00eachent tout Light Body de l\u2019enregistrer fid\u00e8lement. V\u00e9rifiez r\u00e9traction, s\u00e9chage, porte-empreinte, vitesse d\u2019insertion, coordination de l\u2019assistance et temps de travail avant d\u2019incriminer le mat\u00e9riau.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Un produit r\u00e9gulier <a href=\"https:\/\/chemomentmaterials.com\/fr\/\" target=\"_blank\" rel=\"noreferrer noopener\">Mat\u00e9riau d\u2019empreinte VPS<\/a> r\u00e9duit les variations, mais la ma\u00eetrise clinique d\u00e9termine toujours son acc\u00e8s aux zones essentielles.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Le VPS Light Body n\u00e9cessite un soutien stable<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le VPS Light Body ne doit pas porter seul l\u2019empreinte. Il n\u00e9cessite un mat\u00e9riau assez consistant et r\u00e9cup\u00e9rant \u00e9lastiquement pour stabiliser l\u2019enregistrement. Souvent, il enregistre la limite tandis qu\u2019un VPS Medium Body ou Heavy Body soutient le volume.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Si le mat\u00e9riau de soutien est trop mou, insuffisant, mal m\u00e9lang\u00e9 ou retir\u00e9 trop t\u00f4t, la couche fluide peut se d\u00e9former malgr\u00e9 un bon Light Body. Les deux doivent donc \u00eatre \u00e9valu\u00e9s comme un syst\u00e8me.<\/p>\n\n\n\n<p class=\"wp-block-paragraph translation-block\">Le <a href=\"https:\/\/chemomentmaterials.com\/fr\/heavy-body-vps-impression-material\/\" target=\"_blank\" rel=\"noreferrer noopener\">mat\u00e9riau d\u2019empreinte VPS Heavy Body<\/a> Chemoment est con\u00e7u pour le soutien, la r\u00e9cup\u00e9ration \u00e9lastique, la d\u00e9chirure, l\u2019hydrophilie et la stabilit\u00e9 dimensionnelle en cartouche. Pour les couronnes, associez-le \u00e0 un Light Body \u00e0 \u00e9coulement fin, r\u00e9sistant dans les limites minces.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/chemomentmaterials.com\/wp-content\/uploads\/2026\/05\/Dental-procedure-close-up-in-action-1024x576.jpg\" alt=\"Application de mat\u00e9riau d\u2019empreinte avec un porte-empreinte charg\u00e9 pr\u00eat \u00e0 l\u2019emploi\" class=\"wp-image-1039\" style=\"width:692px;height:auto\" srcset=\"https:\/\/chemomentmaterials.com\/wp-content\/uploads\/2026\/05\/Dental-procedure-close-up-in-action-1024x576.jpg 1024w, https:\/\/chemomentmaterials.com\/wp-content\/uploads\/2026\/05\/Dental-procedure-close-up-in-action-300x169.jpg 300w, https:\/\/chemomentmaterials.com\/wp-content\/uploads\/2026\/05\/Dental-procedure-close-up-in-action-768x432.jpg 768w, https:\/\/chemomentmaterials.com\/wp-content\/uploads\/2026\/05\/Dental-procedure-close-up-in-action-1536x864.jpg 1536w, https:\/\/chemomentmaterials.com\/wp-content\/uploads\/2026\/05\/Dental-procedure-close-up-in-action.jpg 1672w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Quand reprendre l\u2019empreinte fait gagner du temps<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Une reprise peut sembler contraignante au rendez-vous, mais elle est souvent plus rapide que g\u00e9rer une couronne \u00e0 limite ouverte, contact trop serr\u00e9, surocclusion ou mauvaise insertion. Ajustage et r\u00e9fection co\u00fbtent aussi du temps d\u2019\u00e9change, de la confiance et de l\u2019organisation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La reprise est g\u00e9n\u00e9ralement pr\u00e9f\u00e9rable pour les limites sous-gingivales, bridges multiples, restaurations implanto-port\u00e9es, secondes molaires et acc\u00e8s ou visibilit\u00e9 limit\u00e9s. Ces cas exigent une empreinte nette et lisible plut\u00f4t qu\u2019une r\u00e9paration \u00e0 interpr\u00e9ter.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Que v\u00e9rifier dans un VPS Light Body ?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La fluidit\u00e9 ne doit pas \u00eatre l\u2019unique crit\u00e8re du VPS Light Body. Il lui faut aussi assez de r\u00e9sistance aux limites fines. Une prise rapide peut am\u00e9liorer l\u2019efficacit\u00e9 mais doit laisser le temps d\u2019injecter, charger et ins\u00e9rer.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u00c9coulement aux limites fines et zones interproximales<\/li>\n\n\n\n<li>Hydrophilie dans des conditions d\u2019humidit\u00e9 r\u00e9alistes<\/li>\n\n\n\n<li>R\u00e9sistance \u00e0 la d\u00e9chirure des fines couches fluides<\/li>\n\n\n\n<li>R\u00e9cup\u00e9ration \u00e9lastique apr\u00e8s retrait des contre-d\u00e9pouilles<\/li>\n\n\n\n<li>Stabilit\u00e9 dimensionnelle \u00e0 la coul\u00e9e et au laboratoire<\/li>\n\n\n\n<li>Temps de travail et de prise en bouche<\/li>\n\n\n\n<li>R\u00e9gularit\u00e9 de la distribution en cartouche<\/li>\n\n\n\n<li>Compatibilit\u00e9 des embouts m\u00e9langeurs<\/li>\n\n\n\n<li>Stabilit\u00e9 d\u2019un lot \u00e0 l\u2019autre<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Pour comparer au-del\u00e0 du catalogue, l\u2019article Chemoment sur <a href=\"https:\/\/chemomentmaterials.com\/fr\/why-vps-impression-materials-tear-or-distort-what-buyers-should-check\/\" target=\"_blank\" rel=\"noreferrer noopener\">les d\u00e9chirures et d\u00e9formations des empreintes VPS<\/a> explique plusieurs d\u00e9faillances fr\u00e9quentes \u00e0 v\u00e9rifier pendant les essais.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Comment tester un syst\u00e8me VPS avant de le distribuer aux cabinets ?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Les distributeurs ne doivent pas juger le VPS seulement sur son nom de viscosit\u00e9 ou son prix. Les cabinets sont habitu\u00e9s \u00e0 des temps, une fermet\u00e9, une sensation au retrait et un comportement aux limites pr\u00e9cis. Un changement est vite remarqu\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Avant de fournir un nouveau VPS, testez couronnes unitaires, bridges, proth\u00e8ses amovibles, couches fines et contre-d\u00e9pouilles mod\u00e9r\u00e9es. V\u00e9rifiez aussi cartouche, embout, dur\u00e9e de conservation, emballage, documents et accompagnement des essais.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Chemoment fournit des silicones par addition et VPS\/PVS pour cabinets, laboratoires, empreintes auriculaires, police scientifique et m\u00e9trologie. La gamme comprend Light Body, Medium Body, Heavy Body, Putty, mat\u00e9riau occlusal, masque gingival et silicones de laboratoire dans sa <a href=\"https:\/\/chemomentmaterials.com\/fr\/\" target=\"_blank\" rel=\"noreferrer noopener\">gamme de silicones par addition et de mat\u00e9riaux d\u2019empreinte VPS<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Le mat\u00e9riau occlusal n\u2019est pas un mat\u00e9riau de r\u00e9paration<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Les silicones en cartouche peuvent se ressembler sans \u00eatre interchangeables. Le mat\u00e9riau occlusal enregistre le rapport d\u2019occlusion ; il ne r\u00e9pare pas une limite de couronne et ne remplace pas le VPS Light Body autour d\u2019une pr\u00e9paration.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le mat\u00e9riau occlusal doit prendre vite, se d\u00e9couper proprement, r\u00e9sister aux d\u00e9formations et rester stable au montage. Le VPS Light Body vise les d\u00e9tails fins de la pr\u00e9paration. Chemoment explique la diff\u00e9rence dans son article sur <a href=\"https:\/\/chemomentmaterials.com\/fr\/putty-vs-bite-registration-material-what-is-the-difference-in-clinical-use\/\" target=\"_blank\" rel=\"noreferrer noopener\">le Putty et le mat\u00e9riau occlusal en clinique<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Recommandation finale<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le rebasage au VPS Light Body peut convenir uniquement \u00e0 un petit d\u00e9faut non critique si l\u2019empreinte est stable et sa r\u00e9insertion exacte. Il ne sauve pas de mani\u00e8re fiable une limite floue, une d\u00e9chirure, une contamination humide, un mouvement ou une d\u00e9formation visible.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour la pr\u00e9cision des couronnes, une reprise nette est souvent plus s\u00fbre. Exposez et ma\u00eetrisez la limite, choisissez un syst\u00e8me VPS compatible, ins\u00e9rez dans le temps imparti et examinez avant envoi.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour les cabinets, laboratoires et distributeurs \u00e9valuant le VPS, Chemoment propose Light Body, Medium Body, Heavy Body, Putty, enregistrement occlusal, masque gingival et silicones de laboratoire. Pour les informations ou \u00e9chantillons, pr\u00e9cisez viscosit\u00e9, travail, prise, format, application et march\u00e9.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">FAQ<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Peut-on r\u00e9parer une empreinte de couronne au VPS Light Body ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Uniquement dans des zones limit\u00e9es non critiques. Si le d\u00e9faut touche limite, zone sous-gingivale, contact adjacent ou pr\u00e9cision d\u2019insertion, une reprise compl\u00e8te est g\u00e9n\u00e9ralement plus s\u00fbre.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Peut-on rebaser sans risque une limite de couronne au VPS Light Body ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">G\u00e9n\u00e9ralement non. Le rebasage peut cr\u00e9er doubles limites, insertion incompl\u00e8te, pression hydraulique ou d\u00e9tails d\u00e9form\u00e9s. Le laboratoire a besoin d\u2019une limite claire, sans zone \u00e0 deviner.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Pourquoi une empreinte rebas\u00e9e peut-elle donner une couronne mal ajust\u00e9e ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Une r\u00e9insertion inexacte peut modifier les rapports entre pr\u00e9paration, dents voisines et occlusion : contacts trop serr\u00e9s, surocclusion, limites ouvertes ou mauvaise insertion.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Faut-il utiliser le VPS Light Body seul pour une couronne ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Non. Le VPS Light Body enregistre surtout les d\u00e9tails fins de la limite. Il n\u00e9cessite g\u00e9n\u00e9ralement le soutien d\u2019un VPS Medium Body ou Heavy Body pour stabilit\u00e9 et pr\u00e9cision dimensionnelle.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Quand reprendre plut\u00f4t que r\u00e9parer ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Reprenez si la limite est floue, la couche d\u00e9chir\u00e9e, la pr\u00e9paration affect\u00e9e par l\u2019humidit\u00e9, le porte-empreinte d\u00e9plac\u00e9 ou si le laboratoire ne distingue pas une limite nette unique.<\/p>","protected":false},"excerpt":{"rendered":"<p>A small void in a crown impression often creates a practical chairside question: add fresh light body VPS and reseat the impression, or take a new one? The answer depends less on the size of the defect and more on where it is, whether the tray can reseat exactly, and whether the lab will receive [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1038,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[3],"tags":[],"class_list":["post-1035","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"_links":{"self":[{"href":"https:\/\/chemomentmaterials.com\/fr\/wp-json\/wp\/v2\/posts\/1035","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chemomentmaterials.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/chemomentmaterials.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/chemomentmaterials.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/chemomentmaterials.com\/fr\/wp-json\/wp\/v2\/comments?post=1035"}],"version-history":[{"count":4,"href":"https:\/\/chemomentmaterials.com\/fr\/wp-json\/wp\/v2\/posts\/1035\/revisions"}],"predecessor-version":[{"id":1218,"href":"https:\/\/chemomentmaterials.com\/fr\/wp-json\/wp\/v2\/posts\/1035\/revisions\/1218"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chemomentmaterials.com\/fr\/wp-json\/wp\/v2\/media\/1038"}],"wp:attachment":[{"href":"https:\/\/chemomentmaterials.com\/fr\/wp-json\/wp\/v2\/media?parent=1035"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/chemomentmaterials.com\/fr\/wp-json\/wp\/v2\/categories?post=1035"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/chemomentmaterials.com\/fr\/wp-json\/wp\/v2\/tags?post=1035"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}